CVE-2023-24796
CVE-2023-24796
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Password vulnerability found in Vinga WR-AC1200 81.102.1.4370 and before allows a remote attacker to execute arbitrary code via the password parameter at the /goform/sysTools and /adm/systools.asp endpoints.
Comprehensive Technical Analysis of CVE-2023-24796
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2023-24796 CVSS Score: 9.8
The CVSS score of 9.8 indicates a critical vulnerability. This score reflects the high severity of the issue, which allows remote attackers to execute arbitrary code. The vulnerability is classified as critical due to its potential for significant impact, including full system compromise, data breaches, and unauthorized access.
2. Potential Attack Vectors and Exploitation Methods
The vulnerability is related to the password parameter at the /goform/sysTools and /adm/systools.asp endpoints. An attacker can exploit this by sending specially crafted requests to these endpoints, which can lead to arbitrary code execution. Potential attack vectors include:
- Remote Code Execution (RCE): By exploiting the password parameter, an attacker can inject malicious code that gets executed on the target system.
- Cross-Site Scripting (XSS): If the input is not properly sanitized, an attacker could inject malicious scripts that execute in the context of the user's session.
- SQL Injection: If the password parameter is used in SQL queries without proper sanitization, an attacker could execute arbitrary SQL commands.
3. Affected Systems and Software Versions
The vulnerability affects Vinga WR-AC1200 devices running firmware version 81.102.1.4370 and earlier. This includes:
- Vinga WR-AC1200: All devices with firmware versions up to and including 81.102.1.4370.
4. Recommended Mitigation Strategies
To mitigate the risk associated with this vulnerability, the following strategies are recommended:
- Firmware Update: Immediately update the firmware to the latest version provided by the vendor. Ensure that the update process is secure and verified.
- Network Segmentation: Isolate vulnerable devices from critical networks to limit the potential impact of an attack.
- Access Control: Implement strict access controls to limit who can access the device's management interfaces.
- Input Validation: Ensure that all input parameters are properly validated and sanitized to prevent injection attacks.
- Monitoring and Logging: Enable comprehensive logging and monitoring to detect any suspicious activities or unauthorized access attempts.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing challenge of securing IoT devices and network equipment. The potential for remote code execution underscores the need for robust security practices, including regular updates, secure coding practices, and proactive monitoring. This vulnerability serves as a reminder that even seemingly innocuous parameters, such as password fields, can be exploited if not properly secured.
6. Technical Details for Security Professionals
Vulnerability Details:
- Affected Endpoints:
/goform/sysToolsand/adm/systools.asp - Vulnerable Parameter: Password
- Exploitation Method: Injection of malicious code via the password parameter
Detection and Response:
- Intrusion Detection Systems (IDS): Configure IDS to detect and alert on suspicious activities targeting the affected endpoints.
- Security Information and Event Management (SIEM): Integrate SIEM solutions to correlate logs and identify potential exploitation attempts.
- Penetration Testing: Conduct regular penetration testing to identify and address similar vulnerabilities in other systems.
References:
By addressing this vulnerability promptly and implementing robust security measures, organizations can significantly reduce the risk of exploitation and protect their networks from potential attacks.