CVE-2023-27012
CVE-2023-27012
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload.
Comprehensive Technical Analysis of CVE-2023-27012
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2023-27012 CVSS Score: 9.8
The vulnerability in question is a stack overflow in the setSchedWifi function of Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn. This type of vulnerability is critical due to its potential to cause a Denial of Service (DoS) or allow for arbitrary code execution. The high CVSS score of 9.8 underscores the severity, indicating that exploitation could have severe impacts on the confidentiality, integrity, and availability of the affected system.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Network-Based Attacks: An attacker could exploit this vulnerability remotely by sending a crafted payload to the
setSchedWififunction. - Local Exploitation: If an attacker gains local access to the device, they could exploit the vulnerability to escalate privileges or execute arbitrary code.
Exploitation Methods:
- Crafted Payload: The attacker can craft a specific payload that overflows the stack buffer in the
setSchedWififunction, leading to code execution or a DoS condition. - Buffer Overflow Techniques: Standard buffer overflow techniques can be employed to overwrite return addresses, function pointers, or other critical data structures.
3. Affected Systems and Software Versions
Affected Systems:
- Tenda AC10 devices running firmware version US_AC10V4.0si_V16.03.10.13_cn.
Software Versions:
- Specifically, the vulnerability is present in the firmware version US_AC10V4.0si_V16.03.10.13_cn.
4. Recommended Mitigation Strategies
Immediate Actions:
- Firmware Update: Ensure that all Tenda AC10 devices are updated to the latest firmware version provided by the vendor.
- Network Segmentation: Isolate affected devices on a separate network segment to limit potential attack vectors.
- Firewall Rules: Implement strict firewall rules to restrict access to the device, allowing only trusted IP addresses.
Long-Term Strategies:
- Regular Patch Management: Establish a regular patch management process to ensure all devices are updated promptly.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious activity that may indicate an exploitation attempt.
- Security Audits: Conduct regular security audits and vulnerability assessments to identify and mitigate potential vulnerabilities.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing challenge of securing IoT devices, which are often deployed in large numbers and can be difficult to update. The potential for remote exploitation and arbitrary code execution makes this vulnerability particularly concerning, as it could be used in broader attacks targeting multiple devices.
6. Technical Details for Security Professionals
Vulnerability Details:
- Function Affected:
setSchedWifi - Type of Vulnerability: Stack overflow
- Exploitation: The vulnerability can be triggered by sending a specially crafted payload that overflows the stack buffer.
Exploitation Steps:
- Identify Target: Identify the Tenda AC10 device running the vulnerable firmware version.
- Craft Payload: Develop a payload that exploits the stack overflow in the
setSchedWififunction. - Deliver Payload: Send the crafted payload to the device, either remotely or locally.
- Execute Code: If successful, the payload will execute arbitrary code or cause a DoS condition.
Mitigation Steps:
- Update Firmware: Apply the latest firmware update from Tenda.
- Network Isolation: Segment the network to isolate vulnerable devices.
- Monitoring: Implement monitoring to detect and respond to any suspicious activity.
References:
Conclusion
CVE-2023-27012 represents a significant risk to organizations using Tenda AC10 devices. Immediate action is required to update firmware and implement mitigation strategies to protect against potential exploitation. Regular security audits and proactive patch management are essential to maintaining a robust cybersecurity posture.