CVE-2023-41552
CVE-2023-41552
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
Comprehensive Technical Analysis of CVE-2023-41552
1. Vulnerability Assessment and Severity Evaluation
CVE-2023-41552 affects Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi devices. The vulnerability is a stack overflow issue triggered by the parameter ssid at the URL /goform/fast_setting_wifi_set. This type of vulnerability can lead to arbitrary code execution, denial of service, or other unintended behaviors.
CVSS Score: 9.8
- Attack Vector (AV): Network
- Attack Complexity (AC): Low
- Privileges Required (PR): None
- User Interaction (UI): None
- Scope (S): Unchanged
- Confidentiality (C): High
- Integrity (I): High
- Availability (A): High
The high CVSS score indicates a critical vulnerability that can be exploited remotely with low complexity, requiring no user interaction or special privileges.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Remote Exploitation: An attacker can send a specially crafted HTTP request to the vulnerable endpoint, causing a stack overflow.
- Network-Based Attacks: Given the nature of the vulnerability, it can be exploited over the network, making it a prime target for remote attackers.
Exploitation Methods:
- Buffer Overflow: By sending a long
ssidparameter, an attacker can overflow the stack buffer, potentially leading to code execution or a crash. - Payload Injection: Crafted payloads can be injected to execute arbitrary code, leading to full system compromise.
3. Affected Systems and Software Versions
Affected Devices:
- Tenda AC7 V1.0 with firmware version V15.03.06.44
- Tenda AC9 V3.0 with firmware version V15.03.06.42_multi
Software Versions:
- The specific firmware versions mentioned above are vulnerable. Other versions may also be affected but have not been explicitly mentioned in the CVE.
4. Recommended Mitigation Strategies
Immediate Actions:
- Firmware Update: Apply the latest firmware updates provided by Tenda. Ensure that the devices are running the most recent, patched versions.
- Network Segmentation: Isolate vulnerable devices from critical networks to limit potential damage.
- Firewall Rules: Implement strict firewall rules to restrict access to the vulnerable endpoint.
Long-Term Strategies:
- Regular Patching: Establish a routine for regularly updating firmware and software.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious network activity targeting the vulnerable endpoint.
- Security Audits: Conduct regular security audits and vulnerability assessments to identify and mitigate similar issues.
5. Impact on Cybersecurity Landscape
Broader Implications:
- IoT Security: This vulnerability highlights the ongoing challenges in securing Internet of Things (IoT) devices, which are often deployed in large numbers and can be difficult to patch.
- Supply Chain Risks: Vulnerabilities in widely used consumer devices can have cascading effects, impacting both home users and businesses.
- Remote Exploitation: The ease of remote exploitation underscores the need for robust network security measures and continuous monitoring.
6. Technical Details for Security Professionals
Exploit Details:
- Endpoint:
/goform/fast_setting_wifi_set - Parameter:
ssid - Vulnerability Type: Stack Overflow
- Exploit Code: Available on GitHub (Referenced URLs)
Detection and Response:
- Log Analysis: Monitor logs for unusual activity related to the
/goform/fast_setting_wifi_setendpoint. - Behavioral Analysis: Use behavioral analysis tools to detect anomalous network traffic patterns.
- Incident Response: Have an incident response plan in place to quickly address any detected exploitation attempts.
References:
Conclusion: CVE-2023-41552 represents a significant risk to users of the affected Tenda devices. Immediate mitigation through firmware updates and network security measures is crucial. The broader cybersecurity community should take note of the vulnerability's implications for IoT security and the importance of proactive defense strategies.