CVE-2023-43198
CVE-2023-43198
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a stack overflow via the popupId parameter in the H5/hi_block.asp function.
Comprehensive Technical Analysis of CVE-2023-43198
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2023-43198
Description: The D-Link device DI-7200GV2.E1 v21.04.09E1 contains a stack overflow vulnerability via the popupId parameter in the H5/hi_block.asp function.
CVSS Score: 9.8
Severity Evaluation:
- CVSS Base Score: 9.8 (Critical)
- Impact Metrics:
- Confidentiality Impact: High
- Integrity Impact: High
- Availability Impact: High
- Exploitability Metrics:
- Attack Vector: Network
- Attack Complexity: Low
- Privileges Required: None
- User Interaction: None
- Scope: Unchanged
The high CVSS score indicates that this vulnerability is critical and poses a significant risk to affected systems. The stack overflow can lead to arbitrary code execution, which can be exploited to gain unauthorized access, execute malicious code, or cause a denial of service (DoS).
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Network-Based Attack: An attacker can exploit this vulnerability over the network by sending specially crafted HTTP requests to the vulnerable endpoint.
- Remote Code Execution (RCE): By exploiting the stack overflow, an attacker can inject malicious code that can be executed on the target device.
- Denial of Service (DoS): An attacker can send malformed requests to crash the device, leading to a DoS condition.
Exploitation Methods:
- Crafted HTTP Requests: An attacker can send HTTP requests with a maliciously crafted
popupIdparameter to trigger the stack overflow. - Buffer Overflow: The attacker can exploit the buffer overflow to inject and execute arbitrary code on the device.
3. Affected Systems and Software Versions
Affected Device:
- D-Link DI-7200GV2.E1
Affected Firmware Version:
- v21.04.09E1
Note: Other versions of the firmware may also be affected, but this specific version is confirmed to be vulnerable.
4. Recommended Mitigation Strategies
Immediate Mitigation:
- Network Segmentation: Isolate the affected device from critical networks to limit the potential impact of an exploit.
- Firewall Rules: Implement strict firewall rules to block unauthorized access to the vulnerable endpoint.
- Monitoring: Increase monitoring and logging for suspicious activities targeting the
H5/hi_block.aspfunction.
Long-Term Mitigation:
- Firmware Update: Apply the latest firmware update from D-Link as soon as it becomes available.
- Patch Management: Implement a robust patch management process to ensure timely updates and patches.
- Security Audits: Conduct regular security audits and vulnerability assessments to identify and mitigate similar vulnerabilities.
5. Impact on Cybersecurity Landscape
Broader Implications:
- IoT Security: This vulnerability highlights the ongoing challenges in securing Internet of Things (IoT) devices, which are often deployed in large numbers and can be difficult to update.
- Supply Chain Risk: The vulnerability in a widely used device underscores the importance of supply chain security and the need for vendors to prioritize security in their products.
- Critical Infrastructure: Devices like the D-Link DI-7200GV2.E1 are often used in critical infrastructure, making this vulnerability particularly concerning for sectors such as healthcare, finance, and government.
6. Technical Details for Security Professionals
Vulnerability Details:
- Function:
H5/hi_block.asp - Parameter:
popupId - Type: Stack Overflow
Exploitation Steps:
- Identify Target: Locate the vulnerable D-Link device on the network.
- Craft Payload: Create a malicious HTTP request with a specially crafted
popupIdparameter designed to overflow the stack. - Send Request: Send the crafted request to the
H5/hi_block.aspendpoint. - Execute Code: If successful, the stack overflow will allow the execution of arbitrary code on the device.
Detection and Response:
- Intrusion Detection Systems (IDS): Deploy IDS to detect and alert on suspicious traffic targeting the
H5/hi_block.aspendpoint. - Log Analysis: Regularly review logs for unusual activity, such as repeated failed requests or unexpected behavior.
- Incident Response: Have an incident response plan in place to quickly address and mitigate any detected exploitation attempts.
Conclusion: CVE-2023-43198 is a critical vulnerability that requires immediate attention from cybersecurity professionals. Organizations using the affected D-Link device should prioritize mitigation efforts to protect against potential exploitation. Regular updates, robust security practices, and proactive monitoring are essential to safeguard against such vulnerabilities.