CVE-2023-51024
CVE-2023-51024
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
TOTOlink EX1800T v9.1.0cu.2112_B20220316 is vulnerable to unauthorized arbitrary command execution in the ‘tz’ parameter of the setNtpCfg interface of the cstecgi .cgi.
Comprehensive Technical Analysis of CVE-2023-51024
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2023-51024 CVSS Score: 9.8
The vulnerability in TOTOlink EX1800T v9.1.0cu.2112_B20220316 allows for unauthorized arbitrary command execution through the ‘tz’ parameter of the setNtpCfg interface in the cstecgi .cgi. This vulnerability is rated with a CVSS score of 9.8, indicating a critical severity level. The high score is due to the potential for complete system compromise, including the execution of arbitrary commands with elevated privileges.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Network-Based Attacks: An attacker can exploit this vulnerability remotely by sending crafted HTTP requests to the vulnerable interface.
- Phishing and Social Engineering: Attackers may trick users into visiting malicious websites that exploit this vulnerability.
Exploitation Methods:
- Command Injection: By manipulating the ‘tz’ parameter in the setNtpCfg interface, an attacker can inject malicious commands that the system will execute.
- Automated Scripts: Attackers can use automated scripts to scan for vulnerable devices and exploit them en masse.
3. Affected Systems and Software Versions
Affected Systems:
- TOTOlink EX1800T devices running firmware version v9.1.0cu.2112_B20220316.
Software Versions:
- Specifically, the vulnerability is present in the cstecgi .cgi script, which handles the setNtpCfg interface.
4. Recommended Mitigation Strategies
Immediate Actions:
- Patch Management: Apply the latest firmware updates provided by TOTOlink.
- Network Segmentation: Isolate vulnerable devices from critical networks to limit potential damage.
- Firewall Rules: Implement strict firewall rules to block unauthorized access to the cstecgi .cgi interface.
Long-Term Strategies:
- Regular Audits: Conduct regular security audits and vulnerability assessments.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious activities related to this vulnerability.
- User Education: Educate users about the risks of phishing and social engineering attacks.
5. Impact on Cybersecurity Landscape
Broader Implications:
- Supply Chain Risks: Vulnerabilities in IoT devices like routers can have cascading effects on supply chain security.
- Increased Attack Surface: The proliferation of IoT devices increases the attack surface, making it crucial to address such vulnerabilities promptly.
- Regulatory Compliance: Organizations must ensure compliance with regulations like GDPR, which mandate robust security measures.
6. Technical Details for Security Professionals
Exploit Details:
- Parameter Manipulation: The ‘tz’ parameter in the setNtpCfg interface is vulnerable to command injection.
- Example Exploit: An attacker might send a request like
http://<device_ip>/cstecgi.cgi?setNtpCfg=tz=;<malicious_command>to execute arbitrary commands.
Detection and Response:
- Log Analysis: Monitor logs for unusual activities related to the cstecgi .cgi script.
- Behavioral Analysis: Use behavioral analysis tools to detect anomalous command executions.
- Incident Response: Have an incident response plan in place to quickly address any detected exploitation attempts.
References:
Conclusion
CVE-2023-51024 represents a critical vulnerability in TOTOlink EX1800T devices that can lead to unauthorized command execution. Immediate patching and robust security measures are essential to mitigate the risk. Organizations should prioritize updating affected devices and implementing comprehensive security strategies to protect against such threats.