CVE-2024-39785
CVE-2024-39785
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- High
- User Interaction
- None
- Scope
- Changed
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Multiple command execution vulnerabilities exist in the nas.cgi add_dir() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists in the adddir_name POST parameter.
Comprehensive Technical Analysis of CVE-2024-39785
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2024-39785 CVSS Score: 9.1
The CVSS score of 9.1 indicates a critical vulnerability. This high score is due to the potential for arbitrary command execution, which can lead to complete system compromise. The vulnerability exists in the nas.cgi add_dir() functionality of the Wavlink AC3000 M33A8.V5030.210505 firmware. The command injection vulnerability in the adddir_name POST parameter allows an attacker to execute arbitrary commands on the affected device.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Authenticated HTTP Request: An attacker with valid credentials can send a specially crafted HTTP request to the vulnerable endpoint.
- Command Injection: The
adddir_namePOST parameter is susceptible to command injection, allowing an attacker to execute arbitrary commands.
Exploitation Methods:
- Crafted HTTP Request: An attacker can craft an HTTP POST request with a malicious payload in the
adddir_nameparameter. - Command Execution: The injected commands can be used to gain unauthorized access, escalate privileges, or perform other malicious activities.
3. Affected Systems and Software Versions
Affected Device:
- Wavlink AC3000
Affected Firmware Version:
- M33A8.V5030.210505
Note: Other versions of the firmware may also be affected, but this specific version is confirmed to be vulnerable.
4. Recommended Mitigation Strategies
Immediate Actions:
- Patch Management: Apply the latest firmware update provided by the vendor to mitigate the vulnerability.
- Access Control: Restrict access to the device's management interface to trusted networks and users.
- Monitoring: Implement monitoring and logging to detect any unusual or unauthorized access attempts.
Long-Term Strategies:
- Regular Audits: Conduct regular security audits and vulnerability assessments.
- Network Segmentation: Segment the network to limit the exposure of critical devices.
- User Education: Educate users on the importance of strong passwords and the risks associated with unauthorized access.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing challenge of securing IoT devices, particularly those used in home and small office environments. The potential for arbitrary command execution underscores the need for robust security measures in firmware development and deployment. This vulnerability can be exploited to compromise network security, steal sensitive information, or launch further attacks within the network.
6. Technical Details for Security Professionals
Vulnerability Details:
- Vulnerable Component:
nas.cgiadd_dir() functionality - Vulnerable Parameter:
adddir_namePOST parameter - Exploitation: Command injection via specially crafted HTTP request
Detection and Response:
- Intrusion Detection Systems (IDS): Configure IDS to detect and alert on suspicious HTTP requests targeting the
nas.cgiendpoint. - Log Analysis: Regularly review logs for any unusual activity or unauthorized access attempts.
- Incident Response: Develop and implement an incident response plan to quickly address any detected exploitation attempts.
Example Exploit Payload:
POST /nas.cgi HTTP/1.1
Host: vulnerable-device
Content-Type: application/x-www-form-urlencoded
Content-Length: 50
adddir_name=test;cat /etc/passwd
Note: The above payload is for illustrative purposes only and should not be used for malicious activities.
Conclusion: CVE-2024-39785 represents a significant risk to the security of Wavlink AC3000 devices running the affected firmware version. Immediate mitigation through firmware updates and access controls is essential to protect against potential exploitation. Ongoing vigilance and proactive security measures are crucial to safeguard against similar vulnerabilities in the future.
References:
This analysis provides a comprehensive overview for cybersecurity professionals to understand and address the vulnerability effectively.