CVE-2024-46048
CVE-2024-46048
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Tenda FH451 v1.0.0.9 has a command injection vulnerability in the formexeCommand function i
Comprehensive Technical Analysis of CVE-2024-46048
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2024-46048 CVSS Score: 9.8
The vulnerability in question is a command injection flaw in the formexeCommand function of Tenda FH451 v1.0.0.9. The CVSS score of 9.8 indicates a critical severity level. This high score is likely due to the potential for complete system compromise, including the execution of arbitrary commands with elevated privileges.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Remote Exploitation: An attacker could exploit this vulnerability remotely by sending crafted HTTP requests to the vulnerable endpoint.
- Local Exploitation: If an attacker gains local access to the device, they could directly manipulate the
formexeCommandfunction to execute arbitrary commands.
Exploitation Methods:
- Command Injection: By injecting malicious commands into the input parameters of the
formexeCommandfunction, an attacker can execute arbitrary system commands. - Privilege Escalation: If the vulnerable function runs with elevated privileges, an attacker could escalate their privileges to gain full control over the device.
3. Affected Systems and Software Versions
Affected Systems:
- Tenda FH451 devices running firmware version v1.0.0.9.
Software Versions:
- Specifically, the vulnerability is present in the
formexeCommandfunction of the firmware version v1.0.0.9.
4. Recommended Mitigation Strategies
Immediate Mitigation:
- Network Segmentation: Isolate affected devices from critical network segments to limit potential damage.
- Access Control: Restrict access to the device to only trusted users and systems.
- Monitoring: Implement continuous monitoring for suspicious activities and anomalies.
Long-Term Mitigation:
- Firmware Update: Apply the latest firmware update from Tenda as soon as it becomes available.
- Patch Management: Ensure a robust patch management process to quickly address future vulnerabilities.
- Security Audits: Conduct regular security audits and vulnerability assessments on all network devices.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing risks associated with IoT devices and network equipment. The potential for remote command execution underscores the need for:
- Enhanced Security Measures: Manufacturers must prioritize security in the design and development of IoT devices.
- Regular Updates: Users and organizations must stay vigilant about applying updates and patches promptly.
- Incident Response: Organizations should have incident response plans in place to quickly address and mitigate such vulnerabilities.
6. Technical Details for Security Professionals
Vulnerability Details:
- The
formexeCommandfunction in Tenda FH451 v1.0.0.9 does not properly sanitize user input, allowing for command injection. - The function is likely used to execute system commands based on user input, making it a critical point of failure.
Exploitation Example:
# Example of a crafted HTTP request to exploit the vulnerability
curl -X POST http://<device_ip>/formexeCommand -d "command=reboot; rm -rf /"
Detection and Prevention:
- Input Validation: Ensure all user inputs are properly validated and sanitized.
- Least Privilege: Run the
formexeCommandfunction with the least privileges necessary. - Intrusion Detection: Implement intrusion detection systems (IDS) to monitor for suspicious command execution patterns.
References:
By addressing this vulnerability promptly and implementing robust security measures, organizations can significantly reduce the risk of exploitation and potential damage.