CVE-2025-51630
CVE-2025-51630
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
TOTOLINK N350RT V9.3.5u.6139_B20201216 was discovered to contain a buffer overflow via the ePort parameter in the function setIpPortFilterRules.
Comprehensive Technical Analysis of CVE-2025-51630
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2025-51630 CVSS Score: 9.8
The vulnerability in question is a buffer overflow in the TOTOLINK N350RT V9.3.5u.6139_B20201216 firmware, specifically within the setIpPortFilterRules function via the ePort parameter. A CVSS score of 9.8 indicates a critical severity level, suggesting that successful exploitation could lead to significant impacts such as remote code execution, denial of service, or unauthorized access to sensitive information.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Remote Exploitation: An attacker could send specially crafted packets to the device, exploiting the buffer overflow to execute arbitrary code or cause a denial of service.
- Local Exploitation: If an attacker has local access to the device, they could exploit the vulnerability to escalate privileges or gain unauthorized access to the device's configuration.
Exploitation Methods:
- Crafted Input: By sending a maliciously crafted input to the
ePortparameter, an attacker could overflow the buffer and inject malicious code. - Fuzzing: Attackers might use fuzzing techniques to identify the exact input that triggers the buffer overflow, allowing them to refine their exploit.
3. Affected Systems and Software Versions
Affected Systems:
- TOTOLINK N350RT routers running firmware version V9.3.5u.6139_B20201216.
Software Versions:
- The vulnerability specifically affects firmware version V9.3.5u.6139_B20201216. Other versions may also be affected but have not been explicitly mentioned in the CVE details.
4. Recommended Mitigation Strategies
Immediate Actions:
- Firmware Update: Users should immediately update to a patched firmware version if available. If no patch is available, consider using alternative firmware or disabling the affected feature if possible.
- Network Segmentation: Isolate the affected devices on a separate network segment to limit potential attack vectors.
- Firewall Rules: Implement strict firewall rules to restrict access to the device, allowing only trusted IP addresses.
Long-Term Strategies:
- Regular Patching: Establish a regular patching schedule to ensure all devices are running the latest firmware.
- Intrusion Detection: Deploy intrusion detection systems (IDS) to monitor for suspicious activity targeting the affected devices.
- Security Audits: Conduct regular security audits to identify and mitigate potential vulnerabilities in network devices.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing challenge of securing IoT and network devices. Buffer overflows remain a common and critical vulnerability, underscoring the need for robust code review processes and secure coding practices. The high CVSS score indicates the potential for significant impact, including widespread exploitation if not addressed promptly.
6. Technical Details for Security Professionals
Vulnerability Details:
- Function:
setIpPortFilterRules - Parameter:
ePort - Issue: Buffer overflow due to insufficient input validation.
Exploitation Steps:
- Identify Target: Locate the TOTOLINK N350RT router running the vulnerable firmware.
- Craft Payload: Develop a payload that exceeds the buffer size for the
ePortparameter. - Deliver Payload: Send the crafted payload to the device, potentially via a network packet or through a web interface.
- Exploit: If successful, the buffer overflow could lead to arbitrary code execution or a denial of service.
Detection and Monitoring:
- Log Analysis: Monitor device logs for unusual activity or error messages related to the
setIpPortFilterRulesfunction. - Network Traffic: Use network monitoring tools to detect anomalous traffic patterns targeting the device.
Conclusion: CVE-2025-51630 represents a critical vulnerability that requires immediate attention. Organizations should prioritize updating affected devices and implementing robust security measures to mitigate the risk of exploitation. Continuous monitoring and regular security assessments are essential to protect against similar vulnerabilities in the future.