CVE-2025-57085
CVE-2025-57085
Weakness (CWE)
CVSS Vector
v3.1- Attack Vector
- Network
- Attack Complexity
- Low
- Privileges Required
- None
- User Interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Description
Tenda W30E V16.01.0.19 (5037) was discovered to contain a stack overflow in the v17 parameter in the UploadCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
Comprehensive Technical Analysis of CVE-2025-57085
1. Vulnerability Assessment and Severity Evaluation
CVE ID: CVE-2025-57085 CVSS Score: 9.8
The vulnerability in question is a stack overflow in the v17 parameter of the UploadCfg function within Tenda W30E V16.01.0.19 (5037). This type of vulnerability is critical due to its potential to cause a Denial of Service (DoS) condition. The high CVSS score of 9.8 indicates a severe risk, reflecting the ease of exploitation and the significant impact it can have on affected systems.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Network-Based Attacks: An attacker can exploit this vulnerability by sending a crafted request to the device over the network.
- Local Attacks: If an attacker has local access to the device, they can manipulate the
v17parameter directly.
Exploitation Methods:
- Crafted Requests: By crafting a specific request that overflows the stack buffer allocated for the
v17parameter, an attacker can cause the device to crash, leading to a DoS condition. - Code Execution: In some cases, stack overflows can be leveraged to execute arbitrary code, although this specific CVE does not mention code execution as a potential outcome.
3. Affected Systems and Software Versions
Affected Systems:
- Tenda W30E devices running firmware version V16.01.0.19 (5037).
Software Versions:
- The vulnerability is specific to firmware version V16.01.0.19 (5037). Other versions may or may not be affected, but this requires further analysis.
4. Recommended Mitigation Strategies
Immediate Actions:
- Firmware Update: If available, update the firmware to a version that addresses this vulnerability.
- Network Segmentation: Isolate affected devices on a separate network segment to limit exposure.
- Firewall Rules: Implement firewall rules to block unauthorized access to the device.
Long-Term Strategies:
- Regular Patching: Ensure that all devices are regularly updated with the latest firmware.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious activity targeting the
UploadCfgfunction. - Security Audits: Conduct regular security audits to identify and mitigate similar vulnerabilities.
5. Impact on Cybersecurity Landscape
The discovery of this vulnerability highlights the ongoing challenge of securing IoT devices. The high CVSS score underscores the potential for significant disruption, particularly in environments where these devices are critical to operations. This vulnerability serves as a reminder of the importance of robust security practices, including regular updates and proactive monitoring.
6. Technical Details for Security Professionals
Vulnerability Details:
- Function:
UploadCfg - Parameter:
v17 - Issue: Stack overflow due to improper bounds checking on the
v17parameter.
Exploitation Steps:
- Identify Target: Locate the Tenda W30E device running the vulnerable firmware version.
- Craft Request: Create a request that exceeds the buffer size allocated for the
v17parameter. - Send Request: Transmit the crafted request to the device, causing a stack overflow and subsequent DoS condition.
Detection:
- Log Analysis: Monitor logs for unusual activity related to the
UploadCfgfunction. - Traffic Monitoring: Use network monitoring tools to detect anomalous traffic patterns targeting the device.
Prevention:
- Input Validation: Ensure that all input parameters are properly validated and sanitized.
- Buffer Management: Implement robust buffer management practices to prevent overflows.
References:
Conclusion
CVE-2025-57085 represents a significant risk to organizations using Tenda W30E devices with the affected firmware version. Immediate mitigation strategies, including firmware updates and network segmentation, are essential to protect against potential exploitation. Long-term, organizations should focus on regular security audits and proactive monitoring to safeguard against similar vulnerabilities. This incident underscores the need for vigilant cybersecurity practices in the management of IoT devices.