Description
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
EPSS Score:
8%
Comprehensive Technical Analysis of EUVD-2023-29197
1. Vulnerability Assessment and Severity Evaluation
The vulnerability EUVD-2023-29197 affects the Tenda AC500 V2.0.1.9(1307) device, specifically in the function fromAddressNat via the parameters entrys and mitInterface. The vulnerability is classified as a Buffer Overflow, which is a critical type of security flaw. The CVSS (Common Vulnerability Scoring System) base score of 9.8 indicates a high severity, reflecting the potential for significant impact if exploited.
- CVSS Vector Breakdown:
- AV:N (Network Vector): The vulnerability can be exploited remotely over the network.
- AC:L (Low Complexity): The attack requires low skill or resources to exploit.
- PR:N (No Privileges Required): No prior authentication is needed to exploit the vulnerability.
- UI:N (No User Interaction): No user interaction is required for the attack to succeed.
- S:U (Unchanged Scope): The vulnerability does not change the security scope.
- C:H (High Confidentiality Impact): Successful exploitation can lead to unauthorized access to sensitive information.
- I:H (High Integrity Impact): The integrity of the system can be compromised.
- A:H (High Availability Impact): The availability of the system can be disrupted.
2. Potential Attack Vectors and Exploitation Methods
Given the nature of the vulnerability, potential attack vectors include:
- Remote Exploitation: An attacker can send specially crafted network packets to the vulnerable device, causing a buffer overflow in the
fromAddressNatfunction. - Denial of Service (DoS): The buffer overflow can lead to a crash or unresponsive state of the device, effectively causing a DoS condition.
- Remote Code Execution (RCE): If the buffer overflow allows for code injection, an attacker could execute arbitrary code on the device, leading to full system compromise.
3. Affected Systems and Software Versions
The vulnerability specifically affects:
- Tenda AC500 V2.0.1.9(1307)
Other versions of the Tenda AC500 may also be affected, but this has not been confirmed. It is advisable to check for updates and patches from the vendor.
4. Recommended Mitigation Strategies
To mitigate the risk associated with this vulnerability, the following strategies are recommended:
- Patch Management: Ensure that the firmware of the Tenda AC500 is updated to the latest version provided by the vendor.
- Network Segmentation: Isolate the vulnerable device from critical network segments to limit potential attack vectors.
- Firewall Rules: Implement strict firewall rules to restrict access to the device, allowing only necessary traffic.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious network activity that may indicate an attempt to exploit this vulnerability.
- Regular Audits: Conduct regular security audits and vulnerability assessments to identify and address potential security issues.
5. Impact on European Cybersecurity Landscape
The vulnerability poses a significant risk to European organizations and individuals using the Tenda AC500 device. Given the high severity and the potential for remote exploitation, it could be leveraged by threat actors to compromise network security, exfiltrate sensitive data, or disrupt services. The widespread use of such devices in both home and enterprise environments amplifies the potential impact.
6. Technical Details for Security Professionals
- Vulnerability Type: Buffer Overflow
- Affected Function:
fromAddressNat - Vulnerable Parameters:
entrysandmitInterface - Exploitation: The vulnerability can be triggered by sending malformed data to the device, causing a buffer overflow in the specified function.
- Detection: Monitor network traffic for unusual patterns or payloads targeting the
fromAddressNatfunction. Use tools like Snort or Suricata to create custom rules for detecting such traffic. - Mitigation: Apply vendor-provided patches as soon as they are available. Implement network-level protections and regularly review security configurations.
Conclusion
EUVD-2023-29197 represents a critical vulnerability in the Tenda AC500 device, with significant potential for exploitation. Organizations and individuals should prioritize updating their devices and implementing robust security measures to mitigate the risk. Continuous monitoring and proactive security management are essential to protect against such threats in the evolving cybersecurity landscape.