Description
VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
EPSS Score:
1%
Comprehensive Technical Analysis of EUVD-2023-38174
1. Vulnerability Assessment and Severity Evaluation
Vulnerability Description:
The EUVD-2023-38174 entry describes an authentication bypass vulnerability in VMware Cloud Director Appliance 10.5 when upgraded from an older version. This vulnerability allows a malicious actor with network access to bypass login restrictions on port 22 (SSH) or port 5480 (appliance management console). The issue stems from an affected version of sssd (System Security Services Daemon) in the underlying Photon OS.
Severity Evaluation:
The vulnerability has a CVSS Base Score of 9.8, which is considered critical. The CVSS vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H indicates:
- Attack Vector (AV): Network
- Attack Complexity (AC): Low
- Privileges Required (PR): None
- User Interaction (UI): None
- Scope (S): Unchanged
- Confidentiality (C): High
- Integrity (I): High
- Availability (A): High
This high severity score underscores the critical nature of the vulnerability, which can lead to unauthorized access and potential compromise of the entire system.
2. Potential Attack Vectors and Exploitation Methods
Attack Vectors:
- Network Access: The attacker needs network access to the VMware Cloud Director Appliance.
- Ports: The vulnerability can be exploited via port 22 (SSH) or port 5480 (appliance management console).
Exploitation Methods:
- Authentication Bypass: The attacker can bypass the login restrictions, gaining unauthorized access to the appliance.
- SSH Access: Exploiting port 22 can allow the attacker to gain shell access, potentially leading to further system compromise.
- Management Console Access: Exploiting port 5480 can allow the attacker to access the management console, potentially leading to administrative actions.
3. Affected Systems and Software Versions
Affected Systems:
- VMware Cloud Director Appliance 10.5 upgraded from an older version.
Affected Software Versions:
- Photon OS versions with
sssdversions lower than 2.8.1-11 (Photon OS 3) or 2.8.2-9 (Photon OS 4 and 5).
Unaffected Systems:
- New installations of VMware Cloud Director Appliance 10.5.
- VMware Cloud Director Appliance 10.5 with updated Photon OS versions.
4. Recommended Mitigation Strategies
Immediate Mitigation:
- Network Segmentation: Isolate the VMware Cloud Director Appliance from untrusted networks.
- Firewall Rules: Implement strict firewall rules to restrict access to ports 22 and 5480.
- Monitoring: Increase monitoring and logging for suspicious activities on the affected ports.
Long-Term Mitigation:
- Update Photon OS: Upgrade the underlying Photon OS to versions that include
sssd2.8.1-11 or higher (Photon OS 3) or 2.8.2-9 or higher (Photon OS 4 and 5). - Patch Management: Ensure regular patching and updating of all software components.
- Access Control: Implement strong access control policies and multi-factor authentication (MFA) where possible.
5. Impact on European Cybersecurity Landscape
Impact Assessment:
- Critical Infrastructure: VMware Cloud Director is widely used in enterprise environments, including critical infrastructure. A successful exploit could lead to significant disruptions.
- Data Breaches: Unauthorized access can result in data breaches, leading to loss of sensitive information.
- Compliance: Organizations may face compliance issues if they fail to address this vulnerability, especially under regulations like GDPR.
Regulatory Considerations:
- ENISA Guidelines: Organizations should follow ENISA guidelines for vulnerability management and incident response.
- Reporting: Ensure timely reporting of incidents to relevant authorities and stakeholders.
6. Technical Details for Security Professionals
Technical Overview:
- Vulnerability Type: Authentication bypass.
- Affected Component:
sssdin Photon OS. - Exploit Conditions: Network access to the appliance and targeting specific ports (22, 5480).
Detection and Response:
- Log Analysis: Analyze logs for unusual login attempts or successful logins without proper authentication.
- Intrusion Detection Systems (IDS): Deploy IDS to detect and alert on suspicious activities.
- Incident Response Plan: Develop and implement an incident response plan specific to this vulnerability.
References:
- VMware Security Advisory
- Photon OS Security Updates
- Photon OS Security Updates
- Photon OS Security Updates
Conclusion: The EUVD-2023-38174 vulnerability poses a significant risk to organizations using VMware Cloud Director Appliance 10.5 upgraded from older versions. Immediate and long-term mitigation strategies are essential to protect against potential exploits. Regular updates and adherence to best practices in cybersecurity will help mitigate the risk and ensure compliance with European cybersecurity regulations.