Description
Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the startIP parameter in the formSetPPTPServer function.
EPSS Score:
0%
Comprehensive Technical Analysis of EUVD-2024-53631
1. Vulnerability Assessment and Severity Evaluation
The vulnerability EUVD-2024-53631 affects Tenda AC18 V15.03.05.19, specifically involving a stack overflow in the startIP parameter within the formSetPPTPServer function. The CVSS (Common Vulnerability Scoring System) base score of 9.8 indicates a critical severity level. The vector string CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H breaks down as follows:
- AV:N (Attack Vector: Network): The vulnerability is exploitable over the network.
- AC:L (Attack Complexity: Low): The attack requires low complexity to exploit.
- PR:N (Privileges Required: None): No privileges are required to exploit the vulnerability.
- UI:N (User Interaction: None): No user interaction is required for the attack to succeed.
- S:U (Scope: Unchanged): The vulnerability does not change the security scope.
- C:H (Confidentiality: High): The vulnerability has a high impact on confidentiality.
- I:H (Integrity: High): The vulnerability has a high impact on integrity.
- A:H (Availability: High): The vulnerability has a high impact on availability.
This high base score underscores the critical nature of the vulnerability, indicating that it poses a significant risk to affected systems.
2. Potential Attack Vectors and Exploitation Methods
The stack overflow vulnerability in the startIP parameter can be exploited by sending a specially crafted request to the formSetPPTPServer function. Potential attack vectors include:
- Remote Code Execution (RCE): An attacker could craft a malicious payload that overflows the stack, leading to arbitrary code execution on the affected device.
- Denial of Service (DoS): The stack overflow could cause the device to crash or become unresponsive, leading to a denial of service.
- Data Exfiltration: If the attacker gains control over the device, they could exfiltrate sensitive data, including network configurations and user credentials.
3. Affected Systems and Software Versions
The vulnerability specifically affects Tenda AC18 devices running firmware version V15.03.05.19. It is crucial to identify all devices within the network that are running this firmware version to assess the extent of the risk.
4. Recommended Mitigation Strategies
To mitigate the risk posed by this vulnerability, the following strategies should be implemented:
- Firmware Update: Immediately update the firmware to a version that addresses this vulnerability. If a patch is not available, consider disabling the PPTP server functionality until a fix is released.
- Network Segmentation: Isolate affected devices on a separate network segment to limit the potential impact of an exploit.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious network activity that may indicate an attempt to exploit this vulnerability.
- Access Controls: Implement strict access controls to limit who can access and configure the device.
- Regular Audits: Conduct regular security audits to identify and address any potential vulnerabilities in the network.
5. Impact on European Cybersecurity Landscape
The vulnerability in Tenda AC18 devices poses a significant risk to European organizations and individuals using these devices. Given the widespread use of Tenda routers, the potential for large-scale exploitation is high. This vulnerability underscores the importance of timely patch management and the need for robust cybersecurity measures to protect against such threats.
6. Technical Details for Security Professionals
For security professionals, the following technical details are pertinent:
- Vulnerability Type: Stack Overflow
- Affected Function:
formSetPPTPServer - Vulnerable Parameter:
startIP - Exploitation Method: Crafting a malicious request to overflow the stack buffer
- Detection: Monitor network traffic for unusual patterns targeting the PPTP server configuration. Use tools like Wireshark to analyze suspicious packets.
- Mitigation: Implement input validation and sanitization for the
startIPparameter to prevent buffer overflows. Ensure that the firmware is updated to the latest version that includes a fix for this vulnerability.
Conclusion
EUVD-2024-53631 represents a critical vulnerability in Tenda AC18 devices that requires immediate attention. Organizations should prioritize updating affected devices and implementing robust security measures to mitigate the risk. Continuous monitoring and regular security audits are essential to maintain a strong cybersecurity posture in the face of such threats.
References