Description
Tenda AC18 V15.03.05.19 was discovered to contain a command injection vulnerability via the usbName parameter in the formSetSambaConf function.
EPSS Score:
1%
Comprehensive Technical Analysis of EUVD-2024-53632
1. Vulnerability Assessment and Severity Evaluation
The vulnerability EUVD-2024-53632, also known as CVE-2024-57583, affects the Tenda AC18 router, specifically version V15.03.05.19. The issue is a command injection vulnerability via the usbName parameter in the formSetSambaConf function. The CVSS (Common Vulnerability Scoring System) base score of 9.8 indicates a critical severity level. The scoring vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H breaks down as follows:
- Attack Vector (AV:N): Network, meaning the vulnerability is exploitable remotely.
- Attack Complexity (AC:L): Low, indicating that the attack is relatively straightforward to execute.
- Privileges Required (PR:N): None, meaning no special privileges are needed to exploit the vulnerability.
- User Interaction (UI:N): None, indicating that no user interaction is required for the attack to succeed.
- Scope (S:U): Unchanged, meaning the vulnerability affects resources managed by the same security authority.
- Confidentiality (C:H): High impact on confidentiality.
- Integrity (I:H): High impact on integrity.
- Availability (A:H): High impact on availability.
This high score underscores the critical nature of the vulnerability, making it a top priority for immediate remediation.
2. Potential Attack Vectors and Exploitation Methods
The command injection vulnerability can be exploited by sending a specially crafted request to the formSetSambaConf function with a malicious usbName parameter. This could allow an attacker to execute arbitrary commands on the affected device with the privileges of the web server process. Potential attack vectors include:
- Remote Exploitation: An attacker can exploit this vulnerability over the network without needing physical access to the device.
- Automated Scripts: Attackers could use automated scripts to scan for vulnerable devices and exploit them en masse.
- Phishing and Social Engineering: Tricking users into visiting malicious websites that exploit the vulnerability.
3. Affected Systems and Software Versions
The vulnerability specifically affects:
- Tenda AC18 Router
- Firmware Version: V15.03.05.19
Other versions of the Tenda AC18 router may also be affected, but this has not been confirmed. It is advisable to check for updates and patches from the vendor.
4. Recommended Mitigation Strategies
To mitigate the risk posed by this vulnerability, the following strategies are recommended:
- Firmware Update: Immediately update the firmware to the latest version provided by Tenda.
- Network Segmentation: Isolate the router from critical networks to limit the potential impact of an exploit.
- Firewall Rules: Implement strict firewall rules to restrict access to the router's management interface.
- Intrusion Detection Systems (IDS): Deploy IDS to monitor for suspicious activity and potential exploitation attempts.
- Regular Audits: Conduct regular security audits and vulnerability assessments to identify and address similar issues.
5. Impact on European Cybersecurity Landscape
The presence of this vulnerability in a widely used consumer router highlights the potential risks to both individual users and organizations. The European cybersecurity landscape could see an increase in attacks targeting home and small business networks, leading to data breaches, unauthorized access, and potential disruption of services. This underscores the need for robust cybersecurity measures and continuous monitoring.
6. Technical Details for Security Professionals
For security professionals, the following technical details are pertinent:
- Exploit Mechanism: The vulnerability is triggered by injecting malicious commands into the
usbNameparameter, which is then executed by theformSetSambaConffunction. - Detection: Monitor network traffic for unusual patterns or requests targeting the
formSetSambaConffunction. Implement logging and alerting for any suspicious activity. - Patch Analysis: Review the patch provided by Tenda to ensure it effectively mitigates the vulnerability. Verify that the input validation and sanitization mechanisms are robust.
- Incident Response: Prepare an incident response plan that includes steps for isolating affected devices, containing the threat, and restoring normal operations.
Conclusion
The command injection vulnerability in Tenda AC18 V15.03.05.19 is a critical issue that requires immediate attention. By understanding the attack vectors, affected systems, and mitigation strategies, cybersecurity professionals can effectively protect against potential exploits and maintain the integrity of their networks. Continuous monitoring and proactive security measures are essential to safeguard against such vulnerabilities in the future.